GENERAL SAFETY

  • Read and understand all instructions and warnings before using or servicing this equipment.
  • Keep these instructions for future reference.
  • Follow all federal, state and local requirements for handling and treatment of battery wash cabinet effluent.
  • Recirculation/Neutralization System (RNS) units are not designed to be shipped or transported after initial delivery.
  • A licensed structural engineer should be consulted prior to installing a RNS on any building level other than the ground floor.
  • Perform system and safety check before operating.
  • Failure to follow these instructions and warnings may result in property damage, personal injury or death.

WORK AREA

  • Keep work area clean and well lit. Cluttered work areas and poor lighting can lead to accidents.
  • Clean up/contain any fluid spills immediately to prevent slips or falls.
  • Be aware of potential hazards when performing any service or maintenance to the unit.

SERVICE & MAINTENANCE

Service personnel shall wear Personal Protective Equipment (PPE) appropriate for the task being performed.

LOCKOUT/TAGOUT

Lockout/tagout the BWC per your corporate policy, if damaged or not functioning properly. Lockout/tagout and deenergize all systems prior to performing any maintenance or service to unit.

LEAD-ACID BATTERIES-EXPLOSION HAZARD

Warning bhs sign (2).JPG

Do not allow open flames or sparks of any kind near a battery. Highly explosive gas is generated when charging a battery that can remain in battery cells for extended periods of time after charging is complete.

  • Always wear appropriate PPE including rubber apron, gloves, boots and full face shield when performing service or maintenance to any lead-acid batteries.
  • Do not place metal or other conductive objects on top of battery. Arcing may occur causing damage to the battery and/or serious personal injury or death.
  • Use only chargers matching the voltage and amperage of the battery being charged. Overcharging a battery can cause damage to the battery, charger and/or serious personal injury or death.
  • Turn off charger before disconnecting battery from charger. Arcing between battery and charger connectors can cause damage to the connectors and/or serious personal injury or death.

BATTERY WASH WATER HAZARDS

Warning bhs sign (2).JPG

HEAVY METALS:

Battery wash water contains heavy metals including (but not limited to) lead and antimony, which through prolonged exposure can lead to serious, long-term, adverse health conditions.

EXTREME pH LEVELS:

Highly acidic (low pH) as well as highly alkaline/ basic (high pH) solutions can cause severe burns, release toxic fumes, and cause violent chemical reactions when mixed with water or when mixed together.

  • pH values outside of the BHS allowable range of 5 to 9 should be treated as “extreme” and caution should be taken to avoid direct contact with such solutions.
  • Always wear appropriate PPE including rubber apron, gloves, boots and full face shield when working in contact with any battery wash water.

TREATMENT CHEMICALS:

Use of chemicals not approved by BHS to treat wash water may result in the release of toxic fumes.


OPERATIONAL SAFETY

OPERATIONAL SAFETY

  • Only personnel trained in the proper and safe operation of RNS units may operate or service the RNS.
  • Operators shall wear appropriate PPE suitable for working with industrial lead-acid batteries while operating the RNS (see prior page).
  • All data plates, warning labels, placards, etc shall be in place and legible at all times. Contact BHS for replacement data plates, warning labels, placards or instructions.
  • All users and service personnel shall be familiar with the meaning and risks associated with all data plates, warning labels, etc.
  • Remove the RNS from service if damaged, defective, or operating improperly (or becomes such while operating) until repairs can be made to correct any problem(s).
  • Only use BHS approved chemicals in the RNS. Severe chemical and/or toxic reactions may result.

DO’s AND DON’T’s

  • DO NOT overfill the RNS reservoir.
  • DO NOT operate the RNS when reservoir is empty.
  • DO NOT modify or fit the RNS with attachments without prior, written approval from BHS.
  • DO NOT operate the RNS with any guard or cover removed unless required for maintenance or repair.
  • Disconnect RNS from all power sources before attempting to perform service or maintenance to the unit.
  • DO NOT immerse any body part into the RNS holding tank water.
  • DO NOT use any chemicals in the RNS that are not approved by BHS.
  • DO NOT use the RNS to wash anything other than industrial lead-acid batteries.
  • DO NOT use foaming type detergents in conjunction with the RNS.
  • DO NOT use soda ash or similar types of neutralizers.
  • Use only fully liquefi ed neutralizers.
  • DO NOT spray personnel or electrical components with spray wand (if equipped).
  • DO NOT use the RNS in a manner for which it is not intended. Some examples of prohibited use are but not limited to:
 » As an emergency wash station 
 » As a parts washer 
 » As a battery room wash-down device 
 » As a battery acid disposal device

DE-ENERGIZATION

  1. Turn the pump release handle counterclockwise to lower the currently selected compartment and relieve any stored hydraulic pressure. See Figure 1
  2. caption

    FIGURE 1

  3. Using the compartment selector valve, select the other compartment and repeat step 1. See Figure 2.
  4. caption

    FIGURE 2

    Warning bhs sign (1).JPG

    Failure to lower the battery compartments when performing service to the BT could result in injury from the compartments lowering unexpectedly

    Failure to release any stored hydraulic pressure could result in injury from:

    • Escaping hydraulic fl uid under high pressure (see HYDRAULIC HAZARDS in the GENERAL SAFETY section).
    • Unexpected movement of hydraulic components.

LABELS & PLACARDS