The following describes the basic installation procedures for the BTC battery transfer carriage.
<ol>
<li>Once the carriage has been removed from the shipping 1. pallet, the floor lock(s) must be attached. The floor lock is attached to the lower frame on the operator side below the lift cylinder with the supplied hardware.  See Figures 1 - 3. </li>
''Notes: BTC-30 units have two floor locks. The floor lock is only to be used when parking the carriage when not in use.''
[[File:IOP-050 BTC (03-29-10)image--039.jpg|300px|none|caption]]
FIGURE 1
[[File:IOP-050 BTC (03-29-10)image--040.jpg|300px|none|caption]]
FIGURE 2
[[File:IOP-050 BTC (03-29-10)image--041.jpg|300px|none|caption]]
FIGURE 3
<li>Ensure that the lift cylinder is properly aligned with the hole located on the underside of the inner frame.  This will ensure safe, even lifting. See Figure 4.</li>
[[File:IOP-050 BTC (03-29-10)image--042.jpg|300px|none|caption]]
FIGURE 4
<li><u>Winch units only:</u> Unbolt the winch support and reposition it toward the rear of the unit.  See Figure 5.
</li>
[[File:IOP-050 BTC p11 figure5.JPG|300px|none|caption]]
FIGURE 5
<li><u>Electric units only:</u>Connect the positive cable to the positive terminal of the battery.  See Figure 6. </li>
''Note: The battery must be disconnected prior to charging.''
[[File:IOP-050 BTC (03-29-10)image--043.jpg|300px|none|caption]]
FIGURE 6
<li>The carriage is now ready for use. </li>
</ol>

Revision as of 16:43, 29 July 2019

TP-619 - SAFETY AND DE-ENERGIZATION PROCEDURES

Register your equipment with BHS Optima, BHS's free app.

GENERAL INFORMATION

The Battery Transfer Carriage (BTC) is used to remove large batteries from electric industrial trucks.

The BTC is either freely maneuvered on casters by a person at the rear of the BTC by pushing/pulling on the handles of the unit or sideways along a designated travel path by a person at either side of the unit pushing/pulling on a handle of the unit.

The BTC can be one of a possible three operating types / options:

  • Fully Mechanical Unit - The unit is raised and lowered using a manual, hydraulic jack located at the rear of the unit. The battery is manipulated by either A) a hand winch located at the rear of the unit that is attached to the battery and retracted, pulling the battery onto the unit while physically pushing the battery by hand off of the unit or B) an extractor arm that moves inward and outward using a hand wheel located on the left, rear of the unit to push or pull the battery on and off the unit.
  • Fully Electric Unit - The unit has a fully enclosed, self contained, electrically powered, hydraulic power unit located on the right, rear of the unit. Power is supplied by a 12VDC battery located on the left, rear of the unit. The power unit provides power to raise the unit using a hydraulic cylinder and power to move the extractor arm inward and outward using a hydraulic motor. The lift and extraction functions are controlled by individual manual lever valves located within the power unit housing. This unit may be equipped with an optional vacuum extraction which has a vacuum pump located between the push handles at the rear of the unit powered by the DC battery.
  • Partially Electric Unit - The unit is a combination of either mechanical extraction and electric lift or electric extraction and mechanical lift. Operation of this unit is a combination of each type listed above.
  • GENERAL SAFETY

    • Read and understand all instructions and warnings before using or servicing this equipment.
    • Keep these instructions for future reference.
    • Battery Transfer Carriage (BTC) units shall only be used indoors in an industrial setting on a hard, nonslip, and level floor without defects including but not limited to holes, gouges, cracks, drains or obstacles comprised of concrete or other suitable industrial material.
    • Forces required to operate the BTC vary with weight of the load, floor conditions, and carriage conditions.
    • BTC units are not designed to be shipped or transported after initial delivery.
    • A licensed structural engineer should be consulted prior to installing a BTC on any building level other than the ground floor.
    • Perform system and safety check before operating.
    • Failure to follow these instructions and warnings may result in property damage, personal injury or death.

    WORK AREA

    • Keep work area clean and well lit. Cluttered work areas and poor lighting can lead to accidents.
    • Clean up/contain any fl uid spills immediately to prevent slips or falls.
    • Be aware of potential hazards when performing any service or maintenance to the unit.

    SERVICE & MAINTENANCE

    Service personnel shall wear Personal Protective Equipment (PPE) appropriate for the task being performed.

    LOCKOUT/TAGOUT

    Lockout/tagout the BTC per your corporate policy, if damaged or not functioning properly. Lockout/tagout and de-energize all systems prior to performing any maintenance or service to unit.

    LEAD-ACID BATTERIES-EXPLOSION HAZARD

    Warning bhs sign (2).JPG

    Do not allow open flames or sparks of any kind near a battery. Highly explosive gas is generated when charging a battery that can remain in battery cells for extended periods of time after charging is complete.

    • Always wear appropriate PPE including rubber apron, gloves, boots and full face shield when performing service or maintenance to any lead-acid batteries.
    • Do not place metal or other conductive objects on top of battery. Arcing may occur causing damage to the battery and/or serious personal injury or death.
    • Use only chargers matching the voltage and amperage of the battery being charged. Overcharging a battery can cause damage to the battery, charger and/or serious personal injury or death.
    • Turn off charger before disconnecting battery from charger. Arcing between battery and charger connectors can cause damage to the connectors and/or serious personal injury or death.

    HYDRAULIC HAZARD

    Warning bhs sign (1).JPG

    AVOID HIGH PRESSURE FLUIDS-Escaping fluid under pressure can penetrate the skin causing serious injury. Relieve pressure before disconnecting hydraulic lines. Tighten all connections before applying pressure. Keep hands and body away from pin holes which eject fluids under high pressure. Use a piece of cardboard or paper to search for leaks. DO NOT use your hand.

    Any fluid injected into the skin under high pressure should be considered a serious medical emergency despite an initial normal appearance of the skin. There will be a delayed onset of pain, and serious tissue damage may occur. Medical attention should be sought immediately.


    OPERATIONAL SAFETY

    OPERATIONAL SAFETY

    • Only personnel trained in the proper and safe operation of BTC units may operate or service the BTC.
    • Operators shall wear appropriate PPE suitable for working with industrial lead-acid batteries while operating the BTC (see prior page).
    • All data plates, warning labels, placards, etc shall be in place and legible at all times. Contact BHS for replacement data plates, warning labels, placards or instructions.
    • All users and service personnel shall be familiar with the meaning and risks associated with all data plates, warning labels, etc.
    • All operators and service personnel shall be aware of potential crush and shear points while operating or servicing the BTC, including the casters and brakes.
    • BTC should be operated in an area with ambient light levels of at least 50 lux.
    • Keep hands and arms out of the battery compartment while operating the BTC.
    • Engage the battery stop(s) and properly secure the battery prior to transporting the battery.
    • Attach the hook and chain (if equipped) to the battery prior to transporting the battery.
    • Avoid abrupt changes in direction when transporting a battery in the BTC to prevent loss of the battery and/or loss of control of the BTC.
    • Remove BTC from service if damaged, defective, or operating improperly (or becomes such while operating) until repairs can be made to correct any problem(s).

    DO’s AND DON’T’s

    • DO NOT exceed the maximum capacity of the BTC.
    • DO NOT modify or fi t the BTC with attachments without prior, written approval from BHS.
    • DO NOT perform any maintenance or service to the BTC with a battery loaded on the BTC.
    • DO NOT allow anyone to ride in or on the BTC.
    • DO NOT operate the BTC with any guard or cover removed unless required for maintenance or repair.
    • DO NOT travel with the stop bar in the raised position.
    • DO NOT lower the inside frame on any person or object.
    • Disconnect the battery (if equipped) before attempting to perform service or maintenance to the BTC.


    • DO NOT use the BTC in a manner for which it is not intended. Some examples of prohibited use are but not limited to:
               >>As a scooter or to transport people 
               >>As a vehicle jack
               >>To lift loads greater than its rated load capacity
               >>Where unintentional movement may exist
               >>Having direct contact with foodstuff
               >>In a potentially explosive atmosphere
    

    DE-ENERGIZATION

    BTC/BTC-MPP:

    1. Turn the pump release handle counterclockwise to lower the inner carriage and release hydraulic pressure. See Figure 1
    2. Warning bhs sign (1).JPG Failure to lower the inner carriage when performing service to the BTC could result in injury from the roller bed lowering unexpectedly.
      caption

      FIGURE 1

    BTC-MPPEL/MPPEE/MPPAE:

    1. Unplug the battery charger (if equipped).
    2. Disconnect the positive cable from the battery post. Secure the positive cable so it cannot contact the positive battery post. See Figure 2.
    3. Warning bhs sign (1).JPG Failure to disconnect electrical power to the BTC could result in electrical shock.
      caption

      FIGURE 2

    4. Cycle the manual valves several times to relieve stored hydraulic pressure. See Figure 3.
    5. Warning bhs sign (1).JPG Failure to release any stored hydraulic pressure could result in injury from: Escaping hydraulic fluid under high pressure (see HYDRAULIC HAZARDS in the GENERAL SAFETY section). Unexpected movement of hydraulic components.
      caption

      FIGURE 3

    LABELS & PLACARDS

    File:IOP-050-BTC-(03-29-10)-8-card.jpg

    GENERAL INFORMATION

    MODEL NUMBER & OPTIONS

    IOP-050-BTC-(03-29-10)-9.jpg

    SPECIFICATIONS

    IOP-050-BTC-(03-29-10)-10.jpg

    INSTALLATION

    The following describes the basic installation procedures for the BTC battery transfer carriage.

    1. Once the carriage has been removed from the shipping 1. pallet, the floor lock(s) must be attached. The floor lock is attached to the lower frame on the operator side below the lift cylinder with the supplied hardware. See Figures 1 - 3.
    2. Notes: BTC-30 units have two floor locks. The floor lock is only to be used when parking the carriage when not in use.

      FIGURE 1

      caption

      FIGURE 2

      caption

      FIGURE 3

    3. Ensure that the lift cylinder is properly aligned with the hole located on the underside of the inner frame. This will ensure safe, even lifting. See Figure 4.
    4. caption

      FIGURE 4

    5. Winch units only: Unbolt the winch support and reposition it toward the rear of the unit. See Figure 5.
    6. caption

      FIGURE 5

    7. Electric units only:Connect the positive cable to the positive terminal of the battery. See Figure 6.
    8. Note: The battery must be disconnected prior to charging.
      caption

      FIGURE 6

    9. The carriage is now ready for use.